Objective <p>To assess the incidence, risk factors, and outcomes of facial palsy following cochlear implantation using the transcanal technique, incorporating radiological predictors.</p> Methods <p>An ambispective observational study involving 978 patients who underwent cochlear implantation via the transcanal technique at three tertiary academic referral center from January 2014 to December 2024. Radiological parameters measured on preoperative computed tomography (CT) scans included facial nerve annulus distance (FAD), facial nerve-round window distance (FNRWD), facial recess width (FRW), alpha angle, and beta angle. Clinical data, including demographics, intraoperative details, and postoperative facial nerve function, were recorded.</p> Results <p>Facial palsy occurred in 7 out of 978 patients (0.71%), all were prelingually deaf children under five years old. Six out of seven had immediate onset facial palsy, with House-Brackmann grades IV-VI. In the non-facial palsy group (<i>n</i> = 971), mean radiological values were: FAD 7.12&#xa0;mm (± 1.08), FRW 4.52&#xa0;mm (± 0.67), and Alpha angle 51.2° (± 4.3°). In the facial palsy group (<i>n</i> = 7), values were 7.05&#xa0;mm (± 1.15), 4.48&#xa0;mm (± 0.73), and 50.1° (± 3.9°), with no significant differences between the groups.</p> Conclusion <p>Facial palsy following the transcanal technique is a rare complication, with an incidence of less than 1 in 100 patients. While reduced FRW and FAD were explored as potential contributors, no statistically significant risk factors could be established.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Clinico-radiological predictors of facial palsy incidence after transcanal cochlear implantation: an ambispective multicenter study

  • Nidhin Das K,
  • Amit Keshri,
  • Rajat Jain,
  • Ravi Sankar Manogaran,
  • Vidhu Sharma,
  • Nazrin Hameed,
  • Mohd Aqib,
  • Kalyan Chidambaram,
  • Mohit Sinha,
  • Amit Goyal

摘要

Objective

To assess the incidence, risk factors, and outcomes of facial palsy following cochlear implantation using the transcanal technique, incorporating radiological predictors.

Methods

An ambispective observational study involving 978 patients who underwent cochlear implantation via the transcanal technique at three tertiary academic referral center from January 2014 to December 2024. Radiological parameters measured on preoperative computed tomography (CT) scans included facial nerve annulus distance (FAD), facial nerve-round window distance (FNRWD), facial recess width (FRW), alpha angle, and beta angle. Clinical data, including demographics, intraoperative details, and postoperative facial nerve function, were recorded.

Results

Facial palsy occurred in 7 out of 978 patients (0.71%), all were prelingually deaf children under five years old. Six out of seven had immediate onset facial palsy, with House-Brackmann grades IV-VI. In the non-facial palsy group (n = 971), mean radiological values were: FAD 7.12 mm (± 1.08), FRW 4.52 mm (± 0.67), and Alpha angle 51.2° (± 4.3°). In the facial palsy group (n = 7), values were 7.05 mm (± 1.15), 4.48 mm (± 0.73), and 50.1° (± 3.9°), with no significant differences between the groups.

Conclusion

Facial palsy following the transcanal technique is a rare complication, with an incidence of less than 1 in 100 patients. While reduced FRW and FAD were explored as potential contributors, no statistically significant risk factors could be established.