Background <p>Corneal allogeneic intrastromal ring segments (CAIRS) are a&#xa0;novel minimally invasive treatment option for keratoconus. Compared to synthetic intracorneal ring segments (ICRS), they offer greater biocompatibility and customizability thanks to the use of allogeneic tissue. The aim is to regularize the curvature of the cornea and improve visual acuity with as few complications as possible.</p> Objective <p>The aim of this review is to summarize and classify the current status of the efficacy, safety, patient selection, graft procurement and nomogram development in CAIRS.</p> Material and methods <p>A&#xa0;narrative literature review of relevant original studies, meta-analyses and review articles on CAIRS was conducted, supplemented by current clinical and technical developments as well as published nomograms (e.g., Jacob, Istanbul, Awwad, Brisbane).</p> Results <p>The literature shows consistent improvements in uncorrected and corrected distance visual acuity, Kmax and spherical equivalent. The CAIRS is associated with a&#xa0;low complication rate. Particularly positive results were achieved with individually customized segment geometry.</p> Conclusion <p>The CAIRS offers a&#xa0;high degree of customization and safety while maintaining good visual efficacy. Targeted patient selection is crucial for a&#xa0;good outcome. In the future, artificial intelligence (AI)-based nomograms could help to further optimize planning and improve the predictability of results.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Korneale allogene intrastromale Ringsegmente

  • Hyeck-Soo Son,
  • Laura Hüfner,
  • Gerd U. Auffarth,
  • Maximilian Friedrich,
  • Victor A. Augustin

摘要

Background

Corneal allogeneic intrastromal ring segments (CAIRS) are a novel minimally invasive treatment option for keratoconus. Compared to synthetic intracorneal ring segments (ICRS), they offer greater biocompatibility and customizability thanks to the use of allogeneic tissue. The aim is to regularize the curvature of the cornea and improve visual acuity with as few complications as possible.

Objective

The aim of this review is to summarize and classify the current status of the efficacy, safety, patient selection, graft procurement and nomogram development in CAIRS.

Material and methods

A narrative literature review of relevant original studies, meta-analyses and review articles on CAIRS was conducted, supplemented by current clinical and technical developments as well as published nomograms (e.g., Jacob, Istanbul, Awwad, Brisbane).

Results

The literature shows consistent improvements in uncorrected and corrected distance visual acuity, Kmax and spherical equivalent. The CAIRS is associated with a low complication rate. Particularly positive results were achieved with individually customized segment geometry.

Conclusion

The CAIRS offers a high degree of customization and safety while maintaining good visual efficacy. Targeted patient selection is crucial for a good outcome. In the future, artificial intelligence (AI)-based nomograms could help to further optimize planning and improve the predictability of results.