<p>We present a custom-built ultra-low expansion (ULE) cavity system designed for high-precision laser frequency stabilization. The cavity mirrors are bonded to the ULE spacer using a low thermal expansion adhesive, and the assembled cavity exhibits a finesse of nearly <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="340_2025_8535_Article_IEq1.gif" Format="GIF" Height="17" Rendition="HTML" Resolution="72" Type="Linedraw" Width="52" /> </InlineMediaObject> <EquationSource Format="TEX">\(3 \times 10^{4}\)</EquationSource> </InlineEquation>. A custom-designed multilayer aluminum housing was developed to passively isolate the cavity from environmental fluctuations. Long-term performance characterization reveals a frequency drift of approximately 164 kHz per day. After locking a diode laser to the cavity using the Pound-Drever-Hall technique, we achieve a linewidth of approximately <InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="340_2025_8535_Article_IEq2.gif" Format="GIF" Height="14" Rendition="HTML" Resolution="72" Type="Linedraw" Width="63" /> </InlineMediaObject> <EquationSource Format="TEX">\(19.4~\text {kHz}\)</EquationSource> </InlineEquation> and a fractional frequency stability of &#xa0;<InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="340_2025_8535_Article_IEq3.gif" Format="GIF" Height="17" Rendition="HTML" Resolution="72" Type="Linedraw" Width="80" /> </InlineMediaObject> <EquationSource Format="TEX">\(6.4 \times 10^{-13}\)</EquationSource> </InlineEquation> at 1&#xa0;s. To validate the reliability of this frequency-stabilized laser system, we applied it to Rydberg excitation spectroscopy via trap-loss measurements of cold <InlineEquation ID="IEq4"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="340_2025_8535_Article_IEq4.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="35" /> </InlineMediaObject> <EquationSource Format="TEX">\( ^{{87}} {\text{Rb}} \)</EquationSource> </InlineEquation>&#xa0;atoms. While the introduction of a custom intermediate circuit (I.C.) already reduces the linewidth from 34 to 6&#xa0;MHz, cavity locking further suppresses frequency fluctuations, as evidenced by the enhanced stability in the trap-loss signal. Our system offers a robust and cost-effective solution for high-resolution spectroscopy, with applications in coherent control of Rydberg atoms.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A custom-built high-finesse reference cavity for cold Rydberg atom excitation

  • Jun-Ren Chen,
  • Yu-Hsuan Chang,
  • Yi-Wei Liu

摘要

We present a custom-built ultra-low expansion (ULE) cavity system designed for high-precision laser frequency stabilization. The cavity mirrors are bonded to the ULE spacer using a low thermal expansion adhesive, and the assembled cavity exhibits a finesse of nearly \(3 \times 10^{4}\) . A custom-designed multilayer aluminum housing was developed to passively isolate the cavity from environmental fluctuations. Long-term performance characterization reveals a frequency drift of approximately 164 kHz per day. After locking a diode laser to the cavity using the Pound-Drever-Hall technique, we achieve a linewidth of approximately \(19.4~\text {kHz}\) and a fractional frequency stability of   \(6.4 \times 10^{-13}\) at 1 s. To validate the reliability of this frequency-stabilized laser system, we applied it to Rydberg excitation spectroscopy via trap-loss measurements of cold \( ^{{87}} {\text{Rb}} \)  atoms. While the introduction of a custom intermediate circuit (I.C.) already reduces the linewidth from 34 to 6 MHz, cavity locking further suppresses frequency fluctuations, as evidenced by the enhanced stability in the trap-loss signal. Our system offers a robust and cost-effective solution for high-resolution spectroscopy, with applications in coherent control of Rydberg atoms.