Objectives <p>Reducing motion artifacts in coronary computed tomography angiography (CCTA) is essential for accurate coronary artery disease assessment. We evaluated the clinical performance of a motion-compensated reconstruction (MCR) using subjective image quality (SIQ) and interpretability of CCTA at varying heart rates (HR).</p> Materials and methods <p>We retrospectively identified 150 patients, grouped by HR (≤ 60, 60–69, ≥ 70 bpm, <i>n</i> = 50 each), referred for prospective ECG-gated CCTA on a spectral dual-layer CT. Two blinded observers independently assessed SIQ on a per-segment (≥ 1.5 mm) and per-patient level using a 4-point Likert scale in 18 coronary segments (78% RR-interval). Sufficient diagnostic interpretability was defined as SIQ ≥ 2. Per-vessel scores were calculated excluding side branch segments. Per-segment SIQ interobserver agreement was assessed using Cohen’s Weighted Kappa. Between MCR and standard reconstruction (SR) at 78% RR-interval, SIQ was compared with Wilcoxon signed-rank tests and diagnostic interpretability and HR-categories using McNemar tests.</p> Results <p>Mean age was 57 (50–64) years, with 50% men, and 1970 included segments. Interobserver agreement was 0.80 for SR and 0.77 for MCR. Positive trends of improved SIQ were seen across all HR-categories and levels, with significant improvements in all but ≥ 70 bpm on a patient level (<i>p</i> = 0.22). Likewise, positive trends were seen for diagnostic interpretability across all levels and HR-categories with significant improvements at the per-segment level for HR &gt; 60 bpm and per-patient level for 61–69 bpm.</p> Conclusion <p>Compared to the standard reconstruction at 78% RR-interval, MCR significantly improves SIQ and diagnostic interpretability in patients referred for CCTA in most HRs and major vessels (≥ 1.5 mm).</p> Key Points <p><Emphasis Type="BoldItalic">Question</Emphasis> <i>Motion artifacts hinder the assessment of coronary arteries on coronary CT angiography (CCTA), leading to more non-diagnostic segments or scans.</i></p> <p><Emphasis Type="BoldItalic">Findings</Emphasis> <i>Compared to the standard reconstruction 78% RR-interval, motion compensated reconstruction (MCR) significantly improves subjective image quality (SIQ) and diagnostic interpretability across heart rate categories.</i></p> <p><Emphasis Type="BoldItalic">Clinical relevance</Emphasis> <i>By integrating multi-phase data into an optimized single-phase reconstruction with improved SIQ and diagnostic interpretability, MCR may reduce the need for multi-phase assessments when the target phase is non-diagnostic.</i></p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Motion compensated reconstruction improves image quality and interpretability of dual-layer coronary CT angiography

  • Philip M. Tetteroo,
  • Niels R. van der Werf,
  • Isabelle Bax,
  • Mani Vembar,
  • Tim Leiner,
  • Pim A. de Jong,
  • Birgitta K. Velthuis,
  • Dominika Suchá

摘要

Objectives

Reducing motion artifacts in coronary computed tomography angiography (CCTA) is essential for accurate coronary artery disease assessment. We evaluated the clinical performance of a motion-compensated reconstruction (MCR) using subjective image quality (SIQ) and interpretability of CCTA at varying heart rates (HR).

Materials and methods

We retrospectively identified 150 patients, grouped by HR (≤ 60, 60–69, ≥ 70 bpm, n = 50 each), referred for prospective ECG-gated CCTA on a spectral dual-layer CT. Two blinded observers independently assessed SIQ on a per-segment (≥ 1.5 mm) and per-patient level using a 4-point Likert scale in 18 coronary segments (78% RR-interval). Sufficient diagnostic interpretability was defined as SIQ ≥ 2. Per-vessel scores were calculated excluding side branch segments. Per-segment SIQ interobserver agreement was assessed using Cohen’s Weighted Kappa. Between MCR and standard reconstruction (SR) at 78% RR-interval, SIQ was compared with Wilcoxon signed-rank tests and diagnostic interpretability and HR-categories using McNemar tests.

Results

Mean age was 57 (50–64) years, with 50% men, and 1970 included segments. Interobserver agreement was 0.80 for SR and 0.77 for MCR. Positive trends of improved SIQ were seen across all HR-categories and levels, with significant improvements in all but ≥ 70 bpm on a patient level (p = 0.22). Likewise, positive trends were seen for diagnostic interpretability across all levels and HR-categories with significant improvements at the per-segment level for HR > 60 bpm and per-patient level for 61–69 bpm.

Conclusion

Compared to the standard reconstruction at 78% RR-interval, MCR significantly improves SIQ and diagnostic interpretability in patients referred for CCTA in most HRs and major vessels (≥ 1.5 mm).

Key Points

Question Motion artifacts hinder the assessment of coronary arteries on coronary CT angiography (CCTA), leading to more non-diagnostic segments or scans.

Findings Compared to the standard reconstruction 78% RR-interval, motion compensated reconstruction (MCR) significantly improves subjective image quality (SIQ) and diagnostic interpretability across heart rate categories.

Clinical relevance By integrating multi-phase data into an optimized single-phase reconstruction with improved SIQ and diagnostic interpretability, MCR may reduce the need for multi-phase assessments when the target phase is non-diagnostic.