<p>Herein, a highly sensitive electrochemical sensor based on poly benzylidene-2-(2,4-dinitrophenyl)hydrazine carbon paste electrode (PBNH/CPE) was developed for the simultaneous determination of acetaminophen (AC) and moxifloxacin (MOX). The sensor fabrication involved electropolymerization of BNH on the carbon paste surface, resulting in enhanced electroactive surface area and improved electrocatalytic performance. The PBNH/CPE exhibited distinct and well-resolved oxidation peaks for AC and MOX, allowing their concurrent detection in phosphate buffer solution (pH 7.0). The sensor demonstrated wide linear ranges (0.025–23.0 µM for AC and 0.03–20.0 µM for MOX), low detection limits (3.6 nM for AC and 6.3 nM for MOX), and excellent selectivity against common interferents, including inorganic ions and organic molecules. The developed method was successfully applied to the determination of AC and MOX in pharmaceutical tablets and human serum samples, achieving recovery values between 96.4% and 100.6%. Furthermore, the sensor displayed good repeatability, reproducibility, and stability over a 30-day period, confirming its practical utility for simultaneous drug detection in complex matrices.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

An efficient novel electrochemical sensor for simultaneous determination of acetaminophen and moxifloxacin based on poly benzylidene-2-(2,4-dinitrophenyl)hydrazine carbon paste electrode

  • Ahmed A. Shamroukh,
  • Mortaga M. Abou-Krisha,
  • Abdulrahman G. Alhamzani,
  • Mouslim Messali,
  • Tarek A. Yousef,
  • Mohamed Abd-Elsabour,
  • M. Khodari

摘要

Herein, a highly sensitive electrochemical sensor based on poly benzylidene-2-(2,4-dinitrophenyl)hydrazine carbon paste electrode (PBNH/CPE) was developed for the simultaneous determination of acetaminophen (AC) and moxifloxacin (MOX). The sensor fabrication involved electropolymerization of BNH on the carbon paste surface, resulting in enhanced electroactive surface area and improved electrocatalytic performance. The PBNH/CPE exhibited distinct and well-resolved oxidation peaks for AC and MOX, allowing their concurrent detection in phosphate buffer solution (pH 7.0). The sensor demonstrated wide linear ranges (0.025–23.0 µM for AC and 0.03–20.0 µM for MOX), low detection limits (3.6 nM for AC and 6.3 nM for MOX), and excellent selectivity against common interferents, including inorganic ions and organic molecules. The developed method was successfully applied to the determination of AC and MOX in pharmaceutical tablets and human serum samples, achieving recovery values between 96.4% and 100.6%. Furthermore, the sensor displayed good repeatability, reproducibility, and stability over a 30-day period, confirming its practical utility for simultaneous drug detection in complex matrices.