Effectiveness and Safety of Image-Guided Renal Biopsies: Insights from 5,235 Procedures in the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) Registry
摘要
This study evaluates the technical success, diagnostic yield, and complication rates of image-guided percutaneous renal biopsies based on multicenter registry data from the German Society for Interventional Radiology and Minimally Invasive Therapy.
Materials and MethodsThis retrospective analysis included 5,235 renal biopsies at 176 centers in Germany, Austria, and Switzerland between 2018 and 2024. Technical success was defined as image-guided confirmed needle placement within the target lesion. Diagnostic yield is defined as proportion of procedures providing adequate samples for clinical diagnosis.
ResultsCT was used for image guidance in 78.53% followed by ultrasound in 12.32%. Technical success was 98.38% and diagnostic yield 94.92%. Technical success was high in both inpatients (98.33%) and outpatients (99.26%; OR = 0.44, 95%CI 0.11–1,80; p = 0.241). The overall complication rate was 5.04%, with major complications in 0.74%. Complications were more frequent with pathological platelet counts and INR values, but none of these coagulation parameters remained independently associated in multivariable analysis. CT-guided biopsies showed higher complication rates than ultrasound-guided procedures, and this association remained after adjustment (adjusted OR 8.57, 95%CI 3.40–21.58; p < 0.001). No fatal complications occurred within 24 h; however, three delayed deaths were documented among hospitalized patients.
ConclusionPercutaneous image-guided renal biopsies are effective and safe, with low complication rates and high diagnostic yield. Ultrasound guidance remained independently associated with a lower complication risk, likely reflecting selection bias.
Graphical abstract