Background <p>Advances in three-dimensional (3D) imaging simulation surgery and 3D-printing have led to the development of patient-specific implants for Asian rhinoplasty. In this study, we present the results of 50 patients who received patient-specific nasal implants after virtual plastic surgery for rhinoplasty.</p> Methods <p>Facial photographs and cone beam computed tomography (CBCT) scan images were obtained preoperatively and at one year postoperatively. We examined whether the patient-specific nasal implant fit exactly well with the nasal bone and was anatomically aligned one year after surgery and how much preoperative virtual simulation surgery matched postoperative clinical results. Additionally, patient and operator satisfaction were evaluated using the Rhinoplasty Outcome Evaluation (ROE) questionnaire and Global Aesthetic Improvement Satisfaction (GAIS).</p> Results <p>The patient-specific nasal implant was anatomically consistent with the surface structure and was aligned with the nasal bone even one year after insertion. The nasal implant remained parallel to the nasal bone one year postoperatively, with an average distance of 0.71 mm in the sagittal view. There was no statistically significant difference in the distance measured from the implant undersurface to the nasal dorsal skin. The difference in distance was approximately 0.01 mm in the bone region and 0.61 mm in the cartilage region. This indicates that the patient’s request was realized by accurately reflecting it in the virtual plastic surgery simulation and patient-specific implants. Additionally, there was an increase in researcher satisfaction (GAIS=1.34) and patient satisfaction (ROE) after surgery by 60%.</p> Conclusions <p>Patient-specific nasal implants fabricated using virtual surgery simulation may be an alternative material for augmentation rhinoplasty.</p> Level of Evidence IV <p>This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors <a href="http://www.springer.com/00266">www.springer.com/00266</a>.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

The Usefulness of 3D-printed Nasal Implant Based on Virtual Plastic Simulation on Asian Rhinoplasty: A 1-Year Follow-Up Study

  • Man Koon Suh,
  • Joo Yun Won,
  • Yo Han Kim,
  • Jae Young Hur,
  • Seong Hyuk Park,
  • Han Kil Moon,
  • Won Jai Lee

摘要

Background

Advances in three-dimensional (3D) imaging simulation surgery and 3D-printing have led to the development of patient-specific implants for Asian rhinoplasty. In this study, we present the results of 50 patients who received patient-specific nasal implants after virtual plastic surgery for rhinoplasty.

Methods

Facial photographs and cone beam computed tomography (CBCT) scan images were obtained preoperatively and at one year postoperatively. We examined whether the patient-specific nasal implant fit exactly well with the nasal bone and was anatomically aligned one year after surgery and how much preoperative virtual simulation surgery matched postoperative clinical results. Additionally, patient and operator satisfaction were evaluated using the Rhinoplasty Outcome Evaluation (ROE) questionnaire and Global Aesthetic Improvement Satisfaction (GAIS).

Results

The patient-specific nasal implant was anatomically consistent with the surface structure and was aligned with the nasal bone even one year after insertion. The nasal implant remained parallel to the nasal bone one year postoperatively, with an average distance of 0.71 mm in the sagittal view. There was no statistically significant difference in the distance measured from the implant undersurface to the nasal dorsal skin. The difference in distance was approximately 0.01 mm in the bone region and 0.61 mm in the cartilage region. This indicates that the patient’s request was realized by accurately reflecting it in the virtual plastic surgery simulation and patient-specific implants. Additionally, there was an increase in researcher satisfaction (GAIS=1.34) and patient satisfaction (ROE) after surgery by 60%.

Conclusions

Patient-specific nasal implants fabricated using virtual surgery simulation may be an alternative material for augmentation rhinoplasty.

Level of Evidence IV

This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.