Purpose <p>The aim of this study was to report the 10-year clinical and radiological outcomes, survivorship, and patient-reported results of the Persona posterior-stabilized (PS) total knee arthroplasty (TKA) performed in a single centre.</p> Methods <p>This retrospective cohort study was based on a prospectively institutional database. A total of 293 primary Persona PS TKAs performed between 2012 and 2015 were identified. After applying inclusion and exclusion criteria, 185 knees (168 patients) were available for analysis at a minimum follow-up of ten years. Clinical evaluation included the Knee injury and Osteoarthritis Outcome Score (KOOS) and the 2011 Knee Society Score (KSS). Radiological assessment consisted of the hip–knee–ankle (HKA) angle. Implant survivorship was analyzed using Kaplan–Meier methods.</p> Results <p>At 10 years, Kaplan–Meier survivorship for revision for any reason was 94.1% (95% CI 90.3–97.9%). Four revisions were performed (2 infections, 2 aseptic loosening). Mean KOOS scores improved significantly from preoperative to ten year follow-up (Pain 48→86; Symptoms 45→84; ADL 50→89; Sport 25→72; QoL 30→82; all <i>p</i> &lt; 0.001). The KSS 2011 domains also significantly improved. The mean postoperative HKA angle was 179° ± 2°, with 7.8% of knees outside ± 3° from neutral. No radiographic evidence of radiolucent lines, osteolysis, or loosening was observed.</p> Conclusion <p>At ten years, the Persona PS knee system demonstrated excellent survivorship and durable functional results comparable to other contemporary TKA designs. Further comparative studies are required to determine whether its morphometric concept provides additional clinical benefit.</p> Level of evidence <p>IV Retrospective cohort study.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Minimum ten years follow-up of total knee arthroplasty using morphometric implants in patients with osteoarthritis

  • Ernest Siret,
  • Fabio Sammartino,
  • Florent Bernard De Villeneuve,
  • Bandar Nasser Al Maeen,
  • Jean-Noel Argenson,
  • Christophe Jacquet

摘要

Purpose

The aim of this study was to report the 10-year clinical and radiological outcomes, survivorship, and patient-reported results of the Persona posterior-stabilized (PS) total knee arthroplasty (TKA) performed in a single centre.

Methods

This retrospective cohort study was based on a prospectively institutional database. A total of 293 primary Persona PS TKAs performed between 2012 and 2015 were identified. After applying inclusion and exclusion criteria, 185 knees (168 patients) were available for analysis at a minimum follow-up of ten years. Clinical evaluation included the Knee injury and Osteoarthritis Outcome Score (KOOS) and the 2011 Knee Society Score (KSS). Radiological assessment consisted of the hip–knee–ankle (HKA) angle. Implant survivorship was analyzed using Kaplan–Meier methods.

Results

At 10 years, Kaplan–Meier survivorship for revision for any reason was 94.1% (95% CI 90.3–97.9%). Four revisions were performed (2 infections, 2 aseptic loosening). Mean KOOS scores improved significantly from preoperative to ten year follow-up (Pain 48→86; Symptoms 45→84; ADL 50→89; Sport 25→72; QoL 30→82; all p < 0.001). The KSS 2011 domains also significantly improved. The mean postoperative HKA angle was 179° ± 2°, with 7.8% of knees outside ± 3° from neutral. No radiographic evidence of radiolucent lines, osteolysis, or loosening was observed.

Conclusion

At ten years, the Persona PS knee system demonstrated excellent survivorship and durable functional results comparable to other contemporary TKA designs. Further comparative studies are required to determine whether its morphometric concept provides additional clinical benefit.

Level of evidence

IV Retrospective cohort study.