Purpose <p>Respiratory motion during data acquisition may compromise image quality and quantitative accuracy of MRI, particularly in patients with limited breath-holding capability. This study aimed to compare hepatic proton density fat fraction (PDFF), T2*, and T2 estimates of the liver obtained from breath-hold (BH) acquisitions with those from corresponding free-breathing respiratory-gated (RG) MRI acquisitions.</p> Methods <p>In this IRB-approved study, healthy controls and patients with liver disease underwent quantitative liver MRI. Hepatic PDFF and T2* were estimated using a confounder-corrected chemical shift-encoded (mDIXON Quant) sequence, and T2 was estimated using a multi-echo Gradient and Spin Echo (mGRASE) sequence with fat suppression, each performed as both BH and RG acquisitions with identical acquisition parameters. Three observers independently drew regions of interest (ROIs) on PDFF, T2*, and T2 maps and agreement between mean values was compared using intraclass correlation coefficients (ICC) and Bland-Altman analysis.</p> Results <p>Nineteen participants (15.4 ± 5.5 years; 9 males) were evaluated. Scan times were 7&#xa0;s and 14&#xa0;s (BH) and 21 ± 6&#xa0;s and 28 ± 4&#xa0;s (RG) for mDIXON Quant and mGRASE respectively. Estimated values from BH acquisitions were: PDFF – median 5% (range 1–43%), T2* – mean 27 ms (range 9–41 ms), and T2 – mean 48 ms (range 34–63 ms). RG and BH acquisitions yielded comparable values with biases of −0.33% [−1.42 to 0.76%] for PDFF, −1.58 ms [−9.50 to 6.33 ms] for T2*, and 0.16 ms [−2.43 to 2.12 ms] for T2, and strong correlations (ICC = 0.99 [0.99, 0.99], 0.85 [0.66, 0.94], and 0.99 [0.97, 0.99] for PDFF, T2*, and T2).</p> Conclusion <p>RG acquisitions provide hepatic PDFF, T2*, and T2 estimates comparable to BH acquisitions without substantial time penalty and are a viable alternative for patients with limited breath-holding ability.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Comparison of hepatic PDFF, T2*, and T2 estimates from breath-hold and free-breathing respiratory-gated MRI acquisitions in children and young adults

  • Anandh Kilpattu Ramaniharan,
  • Justine Kemp,
  • Murat Kocaoglu,
  • Andrew Trout,
  • Jonathan Dillman,
  • Mary Kate Manhard,
  • Amol Pednekar

摘要

Purpose

Respiratory motion during data acquisition may compromise image quality and quantitative accuracy of MRI, particularly in patients with limited breath-holding capability. This study aimed to compare hepatic proton density fat fraction (PDFF), T2*, and T2 estimates of the liver obtained from breath-hold (BH) acquisitions with those from corresponding free-breathing respiratory-gated (RG) MRI acquisitions.

Methods

In this IRB-approved study, healthy controls and patients with liver disease underwent quantitative liver MRI. Hepatic PDFF and T2* were estimated using a confounder-corrected chemical shift-encoded (mDIXON Quant) sequence, and T2 was estimated using a multi-echo Gradient and Spin Echo (mGRASE) sequence with fat suppression, each performed as both BH and RG acquisitions with identical acquisition parameters. Three observers independently drew regions of interest (ROIs) on PDFF, T2*, and T2 maps and agreement between mean values was compared using intraclass correlation coefficients (ICC) and Bland-Altman analysis.

Results

Nineteen participants (15.4 ± 5.5 years; 9 males) were evaluated. Scan times were 7 s and 14 s (BH) and 21 ± 6 s and 28 ± 4 s (RG) for mDIXON Quant and mGRASE respectively. Estimated values from BH acquisitions were: PDFF – median 5% (range 1–43%), T2* – mean 27 ms (range 9–41 ms), and T2 – mean 48 ms (range 34–63 ms). RG and BH acquisitions yielded comparable values with biases of −0.33% [−1.42 to 0.76%] for PDFF, −1.58 ms [−9.50 to 6.33 ms] for T2*, and 0.16 ms [−2.43 to 2.12 ms] for T2, and strong correlations (ICC = 0.99 [0.99, 0.99], 0.85 [0.66, 0.94], and 0.99 [0.97, 0.99] for PDFF, T2*, and T2).

Conclusion

RG acquisitions provide hepatic PDFF, T2*, and T2 estimates comparable to BH acquisitions without substantial time penalty and are a viable alternative for patients with limited breath-holding ability.