Objective <p>The clinical use of magnetic resonance imaging-based volumetric measurement for osteonecrosis of the femoral head (ONFH) is restricted by its complexity. This study aimed to identify a practical computed tomography-based imaging parameter as a reliable alternative to necrotic volume and to evaluate its ability to predict femoral head collapse.</p> Materials and methods <p>This retrospective study included 125 hips from 90 patients with ONFH and initial collapse of &lt; 3&#xa0;mm. Four-dimensional ratios were examined for their association with necrotic volume using generalized estimating equation models. The parameter showing the strongest association was determined by comparing models with the Quasi-likelihood Information Criterion (QIC). Receiver operating characteristic curve analysis was then used to establish a cutoff value for predicting a necrotic volume of ≥ 30%, the threshold defined as severe in the Steinberg classification. This prognostic value of this cutoff for collapse (&gt; 3&#xa0;mm) was tested with a robust Cox proportional hazards model.</p> Results <p>The coronal vertical diameter ratio (CVDR) showed the strongest association with necrotic volume, yielding the lowest QIC. A CVDR cutoff of 51% predicted a large necrotic volume (AUC 0.931). Hips with a CVDR ≥ 51% had a significantly higher risk of collapse compared with those with a CVDR &lt; 51% (HR, 6.07; 95% CI, 3.25–11.34;&#xa0;<i>P</i> &lt; 0.001).&#xa0;This predictive value was consistent across all Japanese Investigation Committee type subgroups.</p> Conclusion <p>The CVDR represents a simple and reliable alternative to volumetric assessment.&#xa0;A cutoff of approximately 51% provides clinically useful risk stratification, and incorporating lesion location may further enhance predictive accuracy.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A simple linear alternative to necrotic volume for predicting collapse in osteonecrosis of the femoral head

  • Keiji Otaka,
  • Yusuke Osawa,
  • Yasuhiko Takegami,
  • Hiroto Funahashi,
  • Hiroaki Ido,
  • Takamune Asamoto,
  • Shinya Tanaka,
  • Shiro Imagama

摘要

Objective

The clinical use of magnetic resonance imaging-based volumetric measurement for osteonecrosis of the femoral head (ONFH) is restricted by its complexity. This study aimed to identify a practical computed tomography-based imaging parameter as a reliable alternative to necrotic volume and to evaluate its ability to predict femoral head collapse.

Materials and methods

This retrospective study included 125 hips from 90 patients with ONFH and initial collapse of < 3 mm. Four-dimensional ratios were examined for their association with necrotic volume using generalized estimating equation models. The parameter showing the strongest association was determined by comparing models with the Quasi-likelihood Information Criterion (QIC). Receiver operating characteristic curve analysis was then used to establish a cutoff value for predicting a necrotic volume of ≥ 30%, the threshold defined as severe in the Steinberg classification. This prognostic value of this cutoff for collapse (> 3 mm) was tested with a robust Cox proportional hazards model.

Results

The coronal vertical diameter ratio (CVDR) showed the strongest association with necrotic volume, yielding the lowest QIC. A CVDR cutoff of 51% predicted a large necrotic volume (AUC 0.931). Hips with a CVDR ≥ 51% had a significantly higher risk of collapse compared with those with a CVDR < 51% (HR, 6.07; 95% CI, 3.25–11.34; P < 0.001). This predictive value was consistent across all Japanese Investigation Committee type subgroups.

Conclusion

The CVDR represents a simple and reliable alternative to volumetric assessment. A cutoff of approximately 51% provides clinically useful risk stratification, and incorporating lesion location may further enhance predictive accuracy.