Purpose <p>We aimed to validate a clinically available artificial intelligence (AI) model to assist general radiologists in the detection of intracranial aneurysm (IA) in a multi-reader multi-case (MRMC) study, and to explore its performance in routine clinical settings.</p> Methods <p>Two distinct cohorts of head CT angiography (CTA) data were assembled to validate an AI model. Cohort 1, comprising gold-standard consecutive CTA cases, was used in an MRMC study involving six board-certified general radiologists. Cohort 2, representing clinical CTA cases, was used to simulate a routine clinical setting. Following these evaluations, an algorithmic audit was conducted to identify any unusual or unexpected behaviors exhibited by the model.</p> Results <p>Cohort 1 consisted of 131 CTA cases, while Cohort 2 included 515 CTA cases. In the MRMC study, the AI-assisted strategy demonstrated a significant improvement in aneurysm diagnostic performance, with the area under the receiver operating characteristic curve increasing from 0.815 (95%CI: 0.754–0.875) to 0.875 (95%CI: 0.831–0.921; <i>p</i> = 0.008). In the AI-based first-reader study, 60.4% of the CTA cases were identified as negative by the AI, with a high negative predictive value of 0.994 (95%CI: 0.977–0.999). The algorithmic audit highlighted two issues for improvement: the accurate detection of tiny aneurysms and the effective exclusion of false-positive lesions.</p> Conclusion <p>This study highlights the clinical utility of a high-performance AI model in detecting IAs, significantly improving general radiologists’ diagnostic performance with the potential to reduce their workload in routine clinical practice. The algorithmic audit offers insights to guide the development and validation of future AI models.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Evaluating a clinically available artificial intelligence model for intracranial aneurysm detection: a multi-reader study and algorithmic audit

  • Bin Hu,
  • Haitao He,
  • Zhao Shi,
  • Li Wang,
  • Quanhui Liu,
  • Zhiyuan Sun,
  • Longjiang Zhang

摘要

Purpose

We aimed to validate a clinically available artificial intelligence (AI) model to assist general radiologists in the detection of intracranial aneurysm (IA) in a multi-reader multi-case (MRMC) study, and to explore its performance in routine clinical settings.

Methods

Two distinct cohorts of head CT angiography (CTA) data were assembled to validate an AI model. Cohort 1, comprising gold-standard consecutive CTA cases, was used in an MRMC study involving six board-certified general radiologists. Cohort 2, representing clinical CTA cases, was used to simulate a routine clinical setting. Following these evaluations, an algorithmic audit was conducted to identify any unusual or unexpected behaviors exhibited by the model.

Results

Cohort 1 consisted of 131 CTA cases, while Cohort 2 included 515 CTA cases. In the MRMC study, the AI-assisted strategy demonstrated a significant improvement in aneurysm diagnostic performance, with the area under the receiver operating characteristic curve increasing from 0.815 (95%CI: 0.754–0.875) to 0.875 (95%CI: 0.831–0.921; p = 0.008). In the AI-based first-reader study, 60.4% of the CTA cases were identified as negative by the AI, with a high negative predictive value of 0.994 (95%CI: 0.977–0.999). The algorithmic audit highlighted two issues for improvement: the accurate detection of tiny aneurysms and the effective exclusion of false-positive lesions.

Conclusion

This study highlights the clinical utility of a high-performance AI model in detecting IAs, significantly improving general radiologists’ diagnostic performance with the potential to reduce their workload in routine clinical practice. The algorithmic audit offers insights to guide the development and validation of future AI models.