<p>The achievement of a comprehensive profiling of plant metabolites has long represented a challenge, not only due to their wide-ranging abundances but also as a result of their considerable chemical diversity. Recent advances in highly sensitive liquid chromatographic (LC) techniques, particularly when coupled with high-resolution mass spectrometry (HRMS), have established metabolomics as a key approach for the analysis of thousands of non-volatile metabolites in crude natural extracts. Nevertheless, the different polarities of primary and secondary metabolites often limit the efficacy of conventional reversed-phase liquid chromatography (RPLC) in providing exhaustive compound coverage. To address this limitation, orthogonal separation techniques such as hydrophilic interaction liquid chromatography (HILIC) should be employed as a complement to RPLC. In this work, four columns with identical geometrical specifications but with different stationary phase chemistry (one reversed-phase C18 and three different HILIC adsorbents) were employed for the untargeted analysis of bioactive compounds contained in <i>Hypericum perforatum</i>. The columns were evaluated not only in terms of chromatographic performance but also based on their ability to resolve challenging isobaric compound pairs of isobaric compounds. Finally, the integration of RPLC and HILIC data enabled a more comprehensive characterization of the metabolites associated with the plant.</p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Comparative evaluation of reversed-phase and hydrophilic interaction liquid chromatography columns for untargeted profiling of bioactive compounds in Hypericum perforatum

  • Davide Barboni,
  • Desiree Bozza,
  • Damiana Natasha Spadafora,
  • Nicoletta Bianchi,
  • Brunilda Myftari,
  • Paola Tedeschi,
  • Chiara De Luca ,
  • Simona Felletti,
  • Matteo Spedicato,
  • Alberto Cavazzini,
  • Martina Catani

摘要

The achievement of a comprehensive profiling of plant metabolites has long represented a challenge, not only due to their wide-ranging abundances but also as a result of their considerable chemical diversity. Recent advances in highly sensitive liquid chromatographic (LC) techniques, particularly when coupled with high-resolution mass spectrometry (HRMS), have established metabolomics as a key approach for the analysis of thousands of non-volatile metabolites in crude natural extracts. Nevertheless, the different polarities of primary and secondary metabolites often limit the efficacy of conventional reversed-phase liquid chromatography (RPLC) in providing exhaustive compound coverage. To address this limitation, orthogonal separation techniques such as hydrophilic interaction liquid chromatography (HILIC) should be employed as a complement to RPLC. In this work, four columns with identical geometrical specifications but with different stationary phase chemistry (one reversed-phase C18 and three different HILIC adsorbents) were employed for the untargeted analysis of bioactive compounds contained in Hypericum perforatum. The columns were evaluated not only in terms of chromatographic performance but also based on their ability to resolve challenging isobaric compound pairs of isobaric compounds. Finally, the integration of RPLC and HILIC data enabled a more comprehensive characterization of the metabolites associated with the plant.

Graphical Abstract