<p>This paper provides a comprehensive discussion on the flow characterization and design of the Mach 5 shock tunnel facility at the Hypersonic Research Center of New Mexico State University (NMSU). It reviews the operational principles of low-enthalpy shock tunnels as well as the measurement techniques employed for the facility characterization. The material and thickness of the secondary diaphragm are shown to significantly affect the stability of stagnation properties. Stagnation conditions are determined through an analysis of pressure–time history data measured in the driven tube. Schlieren flow visualizations over a 10<InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="193_2025_1226_Article_IEq1.gif" Format="GIF" Height="7" Rendition="HTML" Resolution="72" Type="Linedraw" Width="9" /> </InlineMediaObject> <EquationSource Format="TEX">\(^\circ \)</EquationSource> <EquationSource Format="MATHML"><math> <mmultiscripts> <mrow /> <mrow /> <mo>∘</mo> </mmultiscripts> </math></EquationSource> </InlineEquation> half-angle straight cone and a sphere are used to estimate the freestream Mach number. Additionally, femtosecond laser electronic excitation tagging (FLEET) velocimetry is conducted to measure instantaneous velocities in the freestream and turbulent boundary layer flows within the test section. The shock tunnel has a total temperature ranging between 610 and 630 K, with a freestream Mach number of 5.1. The steady test time, as indicated by pitot pressure measurements, ranges from 2 to 2.5&#xa0;ms, while velocimetry and wall-static pressure data suggest that driver gas arrival in the test section occurs approximately 30&#xa0;ms after flow stabilization. The facility was made available for use in undergraduate courses in Fall 2022.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Design and flow characterization of the Mach 5 shock tunnel at New Mexico State University

  • L. Saenz,
  • J. Frankel,
  • A. Gross,
  • F. Shu

摘要

This paper provides a comprehensive discussion on the flow characterization and design of the Mach 5 shock tunnel facility at the Hypersonic Research Center of New Mexico State University (NMSU). It reviews the operational principles of low-enthalpy shock tunnels as well as the measurement techniques employed for the facility characterization. The material and thickness of the secondary diaphragm are shown to significantly affect the stability of stagnation properties. Stagnation conditions are determined through an analysis of pressure–time history data measured in the driven tube. Schlieren flow visualizations over a 10 \(^\circ \) half-angle straight cone and a sphere are used to estimate the freestream Mach number. Additionally, femtosecond laser electronic excitation tagging (FLEET) velocimetry is conducted to measure instantaneous velocities in the freestream and turbulent boundary layer flows within the test section. The shock tunnel has a total temperature ranging between 610 and 630 K, with a freestream Mach number of 5.1. The steady test time, as indicated by pitot pressure measurements, ranges from 2 to 2.5 ms, while velocimetry and wall-static pressure data suggest that driver gas arrival in the test section occurs approximately 30 ms after flow stabilization. The facility was made available for use in undergraduate courses in Fall 2022.