Aims/hypothesis <p>This study aimed to compare the ability of time in tight range (TITR) and time in range (TIR) to predict the achievement of typical glucose management indicator (GMI) and HbA<sub>1c</sub> targets.</p> Methods <p>This cross-sectional analysis included 773 adults with diabetes receiving insulin therapy who visited Samsung Medical Center between June 2019 and December 2023 and wore a Dexcom G6 or FreeStyle Libre continuous glucose monitor for at least 90 days (sensor wear time, ≥70%). A receiver operating characteristic analysis was used to compare the ability of TITR and TIR to predict GMI and HbA<sub>1c</sub> targets.</p> Results <p>TITR had significantly greater AUC values than TIR for predicting GMIs of &lt;53 mmol/mol (7.0%) and &lt;48 mmol/mol (6.5%) among participants using a Dexcom G6 or FreeStyle Libre continuous glucose monitor. TITR also had significantly greater AUC values than TIR for predicting HbA<sub>1c</sub> levels of &lt;53 mmol/mol (7.0%) (95% CI for difference: 0.006, 0.03) and &lt;48 mmol/mol (6.5%) (95% CI for difference: 0.001, 0.03) among participants using the FreeStyle Libre. In the HbA<sub>1c</sub> range of 48–53 mmol/mol (6.5–7.0%), TIR exhibited broader variations than TITR across CV groups. The modifying effect of CV on the association between TITR and GMI or HbA<sub>1c</sub> was minimised around a GMI and HbA<sub>1c</sub> level of 53 mmol/mol (7.0%).</p> Conclusions/interpretation <p>TITR might be a more useful indicator than TIR of the achievement of typical GMI and HbA<sub>1c</sub> targets among adults with diabetes on insulin therapy.</p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Time in tight range and time in range for predicting the achievement of typical glucose management indicator and HbA1c targets

  • Seohyun Kim,
  • Sang Ho Park,
  • Jin A. Lee,
  • So Hyun Cho,
  • Rosa Oh,
  • Ji Yoon Kim,
  • You-Bin Lee,
  • Gyuri Kim,
  • Kyu Yeon Hur,
  • Jae Hyeon Kim,
  • Sang-Man Jin

摘要

Aims/hypothesis

This study aimed to compare the ability of time in tight range (TITR) and time in range (TIR) to predict the achievement of typical glucose management indicator (GMI) and HbA1c targets.

Methods

This cross-sectional analysis included 773 adults with diabetes receiving insulin therapy who visited Samsung Medical Center between June 2019 and December 2023 and wore a Dexcom G6 or FreeStyle Libre continuous glucose monitor for at least 90 days (sensor wear time, ≥70%). A receiver operating characteristic analysis was used to compare the ability of TITR and TIR to predict GMI and HbA1c targets.

Results

TITR had significantly greater AUC values than TIR for predicting GMIs of <53 mmol/mol (7.0%) and <48 mmol/mol (6.5%) among participants using a Dexcom G6 or FreeStyle Libre continuous glucose monitor. TITR also had significantly greater AUC values than TIR for predicting HbA1c levels of <53 mmol/mol (7.0%) (95% CI for difference: 0.006, 0.03) and <48 mmol/mol (6.5%) (95% CI for difference: 0.001, 0.03) among participants using the FreeStyle Libre. In the HbA1c range of 48–53 mmol/mol (6.5–7.0%), TIR exhibited broader variations than TITR across CV groups. The modifying effect of CV on the association between TITR and GMI or HbA1c was minimised around a GMI and HbA1c level of 53 mmol/mol (7.0%).

Conclusions/interpretation

TITR might be a more useful indicator than TIR of the achievement of typical GMI and HbA1c targets among adults with diabetes on insulin therapy.