Background <p>Safe intraosseous&#xa0;(i.o) access as an alternative to intravenous (i.v.) access is essential in the treatment of infants and young children in emergency medicine. However, the literature shows high misplacement rates and insufficient training opportunities for potential users. The aim of this study was to analyze malpunctures in postmortem computed tomography (CT) imaging and to develop and evaluate a&#xa0;realistic, cost-effective three-dimensionally (3D) printed training model for i.o. punctures in children under 2&#xa0;years of age.</p> Materials and methods <p>The CT data from 25&#xa0;deceased children under 2&#xa0;years of age were retrospectively analyzed to document the frequency and type of malpunctures. Based on the findings, a&#xa0;three-part model was produced using filament 3D printing and silicone moulding. The realistic representation of skin, connective tissue, and bone was evaluated by 55&#xa0;experienced users on a&#xa0;Likert scale.</p> Results <p>In 40% of the punctures analyzed, there was incorrect placement, often due to inadequate anatomical assessment. The model developed was rated by the interviewees as suitable for beginner training. Suggestions for improvement mainly concerned haptic skin characteristics and the simulation of the loss of resistance after cortical penetration. Material costs for the training model were around 50 cents per puncture.</p> Conclusion <p>The 3D printed model offers a&#xa0;cost-effective, anatomically precise training option for intraosseous punctures in infants. It can contribute to the improvement of competence and safety during i.o. access, provided it is supplemented by regular training. Future enhancements should further optimize haptic skin characteristics and should provide better feedback on puncture success.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Intraossäre Zugänge bei Säuglingen – Entwicklung eines anatomischen Trainingsmodells

  • Dietrich Stoevesandt,
  • Lina Woydt,
  • Joachim Koppenberg,
  • Michael Wolf,
  • Dmitrij Pinekenstein,
  • Stefan Watzke,
  • Thomas Lange,
  • Sascha Kolokowsky,
  • Simone Hettmer,
  • Hartmut Stefani,
  • Franz Stangl,
  • Martin R. Fischer

摘要

Background

Safe intraosseous (i.o) access as an alternative to intravenous (i.v.) access is essential in the treatment of infants and young children in emergency medicine. However, the literature shows high misplacement rates and insufficient training opportunities for potential users. The aim of this study was to analyze malpunctures in postmortem computed tomography (CT) imaging and to develop and evaluate a realistic, cost-effective three-dimensionally (3D) printed training model for i.o. punctures in children under 2 years of age.

Materials and methods

The CT data from 25 deceased children under 2 years of age were retrospectively analyzed to document the frequency and type of malpunctures. Based on the findings, a three-part model was produced using filament 3D printing and silicone moulding. The realistic representation of skin, connective tissue, and bone was evaluated by 55 experienced users on a Likert scale.

Results

In 40% of the punctures analyzed, there was incorrect placement, often due to inadequate anatomical assessment. The model developed was rated by the interviewees as suitable for beginner training. Suggestions for improvement mainly concerned haptic skin characteristics and the simulation of the loss of resistance after cortical penetration. Material costs for the training model were around 50 cents per puncture.

Conclusion

The 3D printed model offers a cost-effective, anatomically precise training option for intraosseous punctures in infants. It can contribute to the improvement of competence and safety during i.o. access, provided it is supplemented by regular training. Future enhancements should further optimize haptic skin characteristics and should provide better feedback on puncture success.